Material & construction
Single basket chamber with removable perforated basket and bolted/flanged line connections.

Liquid filtration for produced-water pretreatment, pump protection and chemical-service side streams.
| Connection range | NPS 1-6 (DN 25-150) |
|---|---|
| Wetted material | 304L / 316L stainless steel |
| Element interface | Perforated basket; optional mesh liner |
| Design selection | Closure, seal and design pressure/temperature by selected housing |
Industry reference selections; ordered specification requires supplier confirmation.
View catalogue page 37 ↗Single basket chamber with removable perforated basket and bolted/flanged line connections.
Select flange/NPT connections, element count, seals, differential-pressure ports and code construction.
Define screen opening and wire diameter or perforation size, not mesh count alone. Check clean and dirty pressure drop and provide safe drain/cleaning access.
ASME Section VIII where applicable and ordered; code stamp requires evidence for the supplied vessel.
Crate upright or on engineered supports; cap every nozzle and brace closure assemblies.
Share your product IDs, quantities and operating conditions.